Home    Instrumentation    Temperature Measurement    TMS11 iTHERM TMS11 MultiSens Linear Multipoint
TMS1101

TMS11 iTHERM TMS11 MultiSens Linear Multipoint

Modular straight TC and RTD multipoint with primary thermowell

Field of application

The iTHERM TMS11 MultiSens Linear Multipoint thermometer for oil & gas and chemical applications can be customized for various scenarios in compliance with the highest safety standards. It increases process safety by monitoring the temperature on a high number of measuring points along a line using only a single process connection. Easy process integration reduces installation time and thus maximizes plant availability.

  • Oil & Gas industry

  • Heavy chemical processes

  • Petrochemical industry

Benefits

  • Features a primary thermowell for superior mechanical strength and an easy replacement of individual inserts, which are available either with TC or RTD technology

  • Easy integration with inserts according to standards as per IEC 60584, ASTM E230 and IEC 60751

  • Electrical and Pressure Directive compliance for an easy and fast process integration

  • High degree of customization thanks to a modular product design for maximum flexibility, easy installation and maintenance

  • Compliance to various protection classes for use in hazardous areas

  • Possibility to replace individual inserts, even during operation

  • Continuous thermowell integrity monitoring thanks to a pressure port for maximum process safety

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style
    imperial style
    easy-to-use
    suitable for hazardous areas
    process connection: flanged
    light chemical processes
    linear sensor distribution
    modular design
    replaceable sensors during operation

  • Thermowell / protection tube

    with one primary thermowell (for replaceable sensors and increased mechanical protection)

  • Insert / probe

    mineral insulated (MI) sensors in a primary thermowell

  • Outer diameter protection tube / Insert

    48,3mm (1 1/2")
    60,3mm (2")
    76,1mm (2 1/2")
    88,9mm (3")

  • Max. immersion length on request

    up to 15.000,00 mm (590'')

  • Material protection tube/ thermowell

    1.4401 (316)
    1.4435 (316L)
    1.4541 (321)
    1.4845 (310L)
    1.4301 (304)
    1.4307 (304L)

  • Process connection

    flange:
    1 1/2 " ASME/ANSI B16.5 150
    ...900
    2" ASME/ANSI B16.5 150
    ...900
    3" ASME/ANSI B16.5 150
    ..900
    DN40 EN/DIN 1092.1 PN10
    ...PN150
    DN50 EN/DIN 1092.1 PN10
    ...PN150
    DN80 EN/DIN 1092.1 PN10
    ...PN150

  • Tip shape

    straight

  • Operating temperature range

    Type K:
    max. 1.070 °C
    (max. 1.958 °F)
    Type J:
    max. 520 °C
    (max. 968 °F)
    Type N:
    max. 1.100 °C
    (max. 2.012 °F)
    Pt100 WW:
    -200...600 °C
    (-328…1.112 °F)
    Pt100 TF:
    -50…400 °C
    (-58…752 °F)

  • Max. process pressure (static)

    at 20 °C: 240 bar (3481 psi)

  • Accuracy

    class 1 acc. to IEC 60584
    class Special ASTM E230 and ANSI MC 96.1
    IEC60751 Class A
    IEC60751 Class AA

  • Response time

    depending on configuration:
    TC:
    t50 = 21 s
    t90 = 52 s
    RTD:
    t50 = 42 s
    t90 = 108 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX
    IECEX
    UL
    FM
    CSA

  • Certification

    SIL (transmitter only)