RA33 Batch Controller
Field of application
The Batch Controller RA33 is designed to record flow and control output signals for valves and pumps to ensure the exact dosing of predefined batch quantities. The measured volume can be corrected with the temperature/density compensation function. The filling process can be optimized with an automatic or fixed after-run correction. Mineral oils can be corrected according to the ASTM D1250-04 standard.
Recording and controlling of slow batch operations with a duration of longer than 10 seconds. Typical applications include:
-
Food industry
-
Chemical industry
-
Pharmaceutical industry
-
Oil & gas industry
Benefits
-
Fixed and automatic after-run correction for constant, extremely accurate results
-
Higher quality through fast and exact dosing
-
Optional volume correction for mineral oils as per ASTM D1250-04
-
Detailed logging of protocols (preset counter, volume counter, batch name and number) as well as error messages and changes of operating parameters
-
Standard models are suitable for connecting and supplying all common flow transmitters, temperature sensors and density sensors
-
Remote control option to start and abort batch runs
-
Daily, monthly and annual statistics on the batch run size and quantity
-
Measuring principle
Application manager
-
Measuring principle
Batch controller
-
Function
Filling & dosing
-
Calculations
Volume calculation
-
Number of applications
1
-
Data storage
yes
-
Calculation standards
ASTM D1250-04
-
Communication
RS232
USB
Ethernet
Modbus TCP
Modbus RTU -
Power supply
Not defined
-
Loop power supply
Low voltage power supply:
100 bis 230 V AC (-15% / +10%)
Small voltage power supply:
24 V DC (-50% / +75%)
24 V AC (±50%) -
Protection class
IP65
-
Input
1 x analogue (I) / pulse (for flow)
1 x RTD (for temperature)
1 x analogue (I) (for density)
Loop power supply 24V DC (+/-16%) -
Output
1 x analogue (I) / pulse (active)
2 x open collector -
Dimensions (WxHxD)
144 x 144 x 103.1 mm (5.67" x 5.67" x 4.06")
-
Operation
3 operation buttons and 14 function buttons for batch operation or via FieldCare
Read out of historical / logged data via Field Data Manager software (SQL database and visualization interface)
Selectable language -
Display
160 x 80 Dot-Matrix LCD with white backlit
Colour change in case of alarm event
Active display area 70 x 34 mm -
Software functions
Volume calculation
1 or 2 stage operation
Manual and automatic overrun correction
Volume correction factor (VCF) according ASTM D1250-04 for generalized crude oils, refined products and lubricating oils -
Certificates
CE
CSA GP
NTEP (USA)