FMU41 Ultrasonic measurement Time-of-Flight Prosonic
Field of application
The Prosonic FMU41 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.
Two-wire or four wire instrument for continuous non-contact level and flow measurement.
-
Process connection: Thread
-
Temperature: -40 to +80°C (-40 to +176°F)
-
Pressure: +0.7 to +3bar (+10 to +44psi)
-
Maximum measuring distance: Liquids 8m (26ft), Solids 3.5m (11ft)
-
Blocking distance: Liquids and Solids 0.35m (1.15ft)
-
International explosion protection certificates
Benefits
-
Reliable non-contact measurement
-
Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable
-
Envelope curves on the on-site display for simple diagnosis
-
Hermetically sealed and potted sensor
-
Chemically resistant sensor out of PVDF
-
Calibration without filling or discharging
-
Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Compact ultrasonic transmitter
-
Supply / Communication
2-wire HART
-
Accuracy
+/- 2 mm or +/- 0,2 % of set measuring range
-
Ambient temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F) -
Process temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F) -
Process pressure / max. overpressure limit
0.7 bar ... 3 bar abs
(10 psi ... 44 psi) -
Main wetted parts
PVDF
-
Process connection
G / NPT 2"
-
Blocking distance
0.35 m (1.15 ft)
-
Max. measurement distance
Liquids: 8 m (26 ft),
Solids: 3.5 m (11 ft) -
Communication
4...20 mA HART
-
Certificates / Approvals
ATEX, FM, CSA, TIIS, INMETRO, NEPSI
-
Application limits
For higher resistance:
FMU42/FDU9x
Foam / high turbulence possible:
FMU42/FDU91
Fast filling and discharging rate:
FMU90 + FDU9x
Level limit detection:
FMU90 + FDU9x