FMD72 Deltabar
Field of application
The electronic dp Deltabar FMD72 is a differential pressure system, used to measure the pressure, level, volume or mass of liquids in pressurized tanks or distillation columns/evaporators. The high pressure sensor (HP) measures the hydrostatic pressure. The low pressure sensor (LP) measures the head pressure. The level is calculated in the transmitter using these two digital values. The electronic dp system eliminates issues of traditional differential pressure measurements.
For differential pressure, level, volume or mass measurement of liquids in pressurized tanks and distillation columns/evaporators.
-
Process connections: Threads, flanges and hygienic connections
-
Process temperature: -40 to +125°C (-40 to +257°F), optional 250°C (480°F)
-
Measuring range: 400mbar to +40bar (6 to 600psi)
-
Accuracy: Single sensor up to ±0.05%, system up to ±0.07%
-
International explosion protection certificates, hygienic approvals
Benefits
-
Eliminates traditional mechanical issues resulting in greater process availability and reliability
-
Safety risks are minimized with the new electronic differential pressure system architecture and design
-
Lowest total cost of ownership due to reduced installation time, maintenance, downtime and spare requirements
-
Multivariable level measurement: HART-based differential pressure, head pressure and sensor temperatures from one system
-
Continuous health indication of the entire system via HART-based diagnostic
-
High reproducibility and long-term stability
-
Process safety assured with small flush mounted process connections in hygienic applications
-
Measuring principle
Differential pressure
-
Characteristic
Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.
-
Supply voltage
4...20 mA HART:
12...45V DC (Non Ex)
Ex ia: 12...30V DC -
Reference Accuracy
0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor -
Long term stability
0.05% of URL/year of individual sensor
-
Process temperature
–40...+125°C
(–40...+257°F) -
Ambient temperature
–40...+80°C
(–40...+176°F) -
Measuring cell
400 mbar...10 bar
(6 psi...150psi) -
Vacuum resistance
10 mbar (0.15 psi)
-
Max. overpressure limit
160 bar (2400 psi)
-
Process connection
Threads
Flange (DIN, ASME,JIS) -
Process connection hygienic
DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent -
Material process membrane
316L, AlloyC,
-
Fill fluid
Silicone oil
Synthetic oil -
Material housing
Die-cast aluminum
Stainless steel -
Communication
4...20 mA HART
-
Certificates / Approvals
ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex
-
Design approvals
NACE MR0175,
EN10204-3.1, -
Hygienic approvals
EHEDG
3A