DTI200 Magphant electromagnetic flowmeter
Field of application
The cost-effective, compact limit switch Magphant is an ideal flowmeter for water applications in Utilities. Its reliable measurement with high repeatability allows for univesal and easy use and supports safe process- and plant operation.
-
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
-
Universally usable for all water applications in Utilities.
Device properties
-
Compact, space-saving design
-
Nominal diameter: DN 15 to 2000 (1/2 to 80")
-
Applicable for steel or plastic pipes
-
Switch point setting via rotary switch
-
Current output and relay output
-
ATEX, FM, CSA
Benefits
-
High plant availability – reliable flow information
-
Energy-saving flow measurement – no pressure loss due to cross-section constriction
-
Maintenance-free – no moving parts
-
Process safety – device self-monitoring and reliable monitoring even with empty piping
-
Product safety – integrated testing to check correct functioning of the electronics
-
Easy operation – potentiometer setting of full-scale value
-
Measuring principle
Electromagnetic
-
Product headline
.
-
Sensor features
High plant availability – reliable flow information. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts. Compact, space-saving design. Nominal diameter: DN 15 to 2000 (½ to 80").
-
Transmitter features
Process safety – device self-monitoring and reliable monitoring even with empty piping. Product safety – integrated testing to check correct functioning of the electronics. Easy operation – potentiometer setting of full-scale value. Switch point setting via rotary switch. Current output and relay output.
-
Nominal diameter range
DN15 to DN2000
1/2" to 80" -
Wetted materials
1.4435/316L
-
Measured variables
Volume flow
-
Max. measurement error
2%
-
Measuring range
0 to 56'550 m3/h
-
Max. process pressure
0 to 16 bar abs
-
Medium temperature range
-20 to +120°C
(-4 to +248°F) -
Ambient temperature range
-20...60 °C (-4 to 140°F)
-
Sensor housing material
Die-cast aluminium, epoxy powder coated
-
Degree of protection
IP 66 / NEMA 4X / Type 4X
-
Display/Operation
Test function
-
Outputs
4 to 20 mA
Relay -
Inputs
None
-
Power supply
24 V DC (20...30 V DC)
-
Hazardous area approvals
FM
CSA -
Product safety
CE, EAC